1. Instrument
a. HPLC-9a(Shimadzu)
b. Sartorius electronic balance(Germany)
c. KQ-----model 100, Washing device of ultrasonic wave 100-KQ
2. Condition
Chromatographic Column ќ ROM-150 ODS-c18(4.6mm×250mm, 5ц)
Mobile Phase: methanol : Water:Acetic Acid =80:20:0.1
Flow Rate:1.0mL/min
Wave Length: 254nm
Column: room temperature:25℃
3.Standard solution
Transfer about 5 mg sample of aloe-emodin standard powder , accurately weighed, to a 25mL volumetric flask, add the right amount methanol to dissolve, Ultrasonic wave is shaken for 5 minutes till all dissolve in the methanol solution. Then add water to scale mark, it is obtained.
4.Testing solution
Transfer 5 mg sample of aloe-emodin powder, accurately weighed, to a 25ml volumetric flask, add the right
amount methanol to dissolve, Ultrasonic wave is shaken for 5 minutes till all dissolve in the methanol, Then add methanol to scale mark,shake evenly, it is obtained.
5. Procedure
Separately inject equal volumes (20uL) of the Standard preparation and the Assay preparation into the chromatograph, record th chromatograms, and measure the responses for the major peaks.
6. Content calculation
A1 W2
X%=-----×----×100%
A2 W1
For any inquiry or further information, welcome contact info@natural-field.com. Natural Field Ltd. would always provide you an all-in-one solution.